
EH-TMASS-F300
| Measuring Principle : Thermal Mass Flow (Inline) | Application : Utility and process gases, gas mixtures in small line sizes |
| Size Range : DN15-100 (½"-4") | Brand : Endress+Hauser |

EH-TMASS-I300
| Measuring Principle : Thermal Mass Flow (Insertion) | Application : Utility and process gases and gas mixtures in circular piping or rectangular ducts |
| Size Range : DN80-1500 (3"-60") | Brand : Endress+Hauser |

EH-TMASS-I500
| Measuring Principle : Thermal Mass Flow (Insertion) | Application : Utility and process gases and gas mixtures in circular piping or rectangular ducts |
| Size Range : DN80-1500 (3"-60") | Brand : Endress+Hauser |

EH-PROWIRL-F200
| Measuring Principle : Vortex | Application : Steam (including wet steam), gases and liquids |
| Size Range : DN15-300 (½"-12") | Brand : Endress+Hauser |

EH-PROSONIC-G500
| Measuring Principle : Ultrasonic (Gas) | Application : Natural and process gas in the chemical, oil and gas industries |
| Size Range : DN25-300 (1"-12") | Brand : Endress+Hauser |

EH-PROSONIC-G300
| Measuring Principle : Ultrasonic (Gas) | Application : Natural and process gas in the chemical, oil and gas industries |
| Size Range : DN25-300 (1"-12") | Brand : Endress+Hauser |

EH-PROSONIC-B200
| Measuring Principle : Ultrasonic (Gas) | Application : Wet biogas and digester gas |
| Size Range : DN50-200 (2"-8") | Brand : Endress+Hauser |

EH-PROMASS-F300
| Measuring Principle : Coriolis (Mass Flow) | Application : Liquids and gases under varying, demanding process conditions |
| Size Range : DN8-250 (⅜"-10") | Brand : Endress+Hauser |

EH-PROMASS-A300
| Measuring Principle : Coriolis (Mass Flow) | Application : Liquids and gases at lowest flow rates, all industries |
| Size Range : DN1-4 (1/24"-1/8") | Brand : Endress+Hauser |

EH-PROMASS-E300
| Measuring Principle : Coriolis (Mass Flow) | Application : Liquids and gases in a wide range of standard applications |
| Size Range : DN8-80 (⅜"-3") | Brand : Endress+Hauser |

EH-PROMASS-E500
| Measuring Principle : Coriolis (Mass Flow) | Application : Liquids and gases in a wide range of standard applications |
| Size Range : DN8-80 (⅜"-3") | Brand : Endress+Hauser |

EH-PROMASS-F500
| Measuring Principle: Coriolis | Application: Liquids and gases under varying, demanding process conditions |
| Size Range: DN 8 to 250 (⅜" to 10") | Brand: Endress+Hauser |

EH-PROMASS-I300
| Measuring Principle: Coriolis | Application: Liquids and gases needing low pressure loss and gentle fluid treatment, with in-line viscosity measurement |
| Size Range: DN 8 to 80 (⅜" to 3") | Brand: Endress+Hauser |

EH-PROMASS-K10
| Measuring Principle: Coriolis | Application: Basic mass flow tasks such as air, gas, fuel and water; utility processes |
| Size Range: DN 8 to 80 (⅜" to 3") | Brand: Endress+Hauser |

EH-PROMASS-Q300
| Measuring Principle: Coriolis | Application: Highest-accuracy mass flow, volume flow and density; custody transfer and liquids with entrained gas |
| Size Range: DN 25 to 250 (1" to 10") | Brand: Endress+Hauser |

EH-PROMASS-Q500
| Measuring Principle: Coriolis | Application: Highest-accuracy mass flow, volume flow and density; custody transfer and liquids with entrained gas |
| Size Range: DN 25 to 250 (1" to 10") | Brand: Endress+Hauser |

EH-PROMAG-P300
| Measuring Principle: Electromagnetic | Application: Chemical and process applications with corrosive liquids and high medium temperatures |
| Size Range: DN 15 to 600 (½" to 24") | Brand: Endress+Hauser |

EH-PROMAG-H100
| Measuring Principle: Electromagnetic | Application: Hygienic applications in the food and beverage and life sciences industries |
| Size Range: DN 2 to 150 (1/12" to 6") | Brand: Endress+Hauser |

EH-PROMAG-W400
| Measuring Principle: Electromagnetic | Application: Water and wastewater: drinking water, utility water, industrial and municipal wastewater |
| Size Range: DN 25 to 3000 (1" to 120") | Brand: Endress+Hauser |

EH-PROMAG-H300
| Measuring Principle: Electromagnetic | Application: Hygienic applications in the food and beverage and life sciences industries |
| Size Range: DN 2 to 150 (1/12" to 6") | Brand: Endress+Hauser |

EH-PROMAG-P200
| Measuring Principle: Electromagnetic | Application: Chemical and process applications with corrosive liquids and high medium temperatures |
| Size Range: DN 15 to 200 (½" to 8") | Brand: Endress+Hauser |

EH-PROMAG-P500
| Measuring Principle: Electromagnetic | Application: Chemical and process applications with corrosive liquids and high medium temperatures |
| Size Range: DN 15 to 600 (½" to 24") | Brand: Endress+Hauser |

EH-PROMAG-P10
| Measuring Principle: Electromagnetic | Application: Basic process applications with corrosive liquids and high medium temperatures |
| Size Range: DN 15 to 600 (½" to 24") | Brand: Endress+Hauser |

EH-PROMAG-W10
| Measuring Principle: Electromagnetic | Application: Basic water and wastewater applications, such as raw water intake |
| Size Range: DN 25 to 3000 (1" to 120") | Brand: Endress+Hauser |

EH-PICOMAG
| Measuring Principle: Electromagnetic | Application: Conductive liquids in secondary circuits; process quality control and monitoring in utilities |
| Size Range: DN 15 to 50 (½" to 2") | Brand: Endress+Hauser |

EH-PROMAG-55S
| Measuring Principle: Electromagnetic | Application: Inhomogeneous, abrasive and corrosive fluids with high solids content |
| Size Range: DN 15 to 600 (½" to 24") | Brand: Endress+Hauser |